• Immunohistochemistry (IHC)

Progesterone Receptor (PR) belongs to a superfamily of nuclear hormone receptors. Estrogen Receptor (ER) induces PR expression, therefore, PR status serves as an indicator of an intact ER pathway. There are two known isoforms of PR; PRα and PRß. The current assays in clinical breast cancer measure both isoforms. PR is expressed in about 60-70% of invasive breast cancers. It is a weak prognostic factor by itself but a modest predictive factor that adds to the predictive value of ER for response to endocrine therapies, both in adjuvant and metastatic settings. The primary indication to assess PR in breast cancer is to predict response to hormonal therapies, such as tamoxifen, other selective estrogen receptor modulators (SERMs) and aromatase inhibitors.

Specimen Requirements

Preferred specimen (FFPE block):
A formalin-fixed, paraffin-embedded (FFPE) tissue block is the preferred specimen type. Use 10% NBF fixative; do not use zinc or mercury fixatives.
If submitting slides (instead of a block):
Submit the following. All slides cut at 4–5 microns. Please use positively-charged slides and 10% NBF fixative.
H&E slide: One (1) unbaked, unstained slide for H&E staining (required)
Cut Slides: Two (2) positively charged unstained slides for each IHC test/antibody ordered
Specimen identification:
Block and slide identifiers should be clearly written and match exactly with the specimen ID and specimen labeling as noted on the requisition.

Storage and Transportation

Slides may be stored at room temperature; transport with cold pack, making sure cold pack is not in direct contact with specimen.
NYS Clients: Please provide Date and Time of Collection.

CPT Code(s)*

88342 x 1 or 88341 x 1 (qualitative IHC) or 88360 (quantitative/semi-quantitative, manual) or 88361 x 1 (quantitative/semi-quantitative, computer assisted)
Turnaround time
1-2 Days

Image Analysis for Global: 2 Days
Image Analysis for (Tech-Only): 2 Days
Tech-Only (stain only): 24 Hours

Level of Service

  • Global
  • Tech Only

Integrations

Request electronic integrations →

New York Approved: Yes

*The CPT codes provided with our test descriptions are based on AMA guidelines and are for informational purposes only. Correct CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed.

Biomarkers

Immunohistochemistry (IHC)
Expression
PGR

Last Updated: March 19, 2026

Get in touch

Our Client Services team is on hand to help. Please call us at 866.776.5907, Option 3.